Laporkan Masalah

Perbandingan Volume Beton Hasil Perancangan Gedung Dengan Dinding Basement Menyatu Pada Rangka dan Terpisah (Studi Kasus Perancangan Ulang Gedung Laboratorium Bahan Bangunan DTSL FT UGM Dengan Dua Lantai Basement)

M FIKRI ANANDA H, Dr.- Ing. Ir. Andreas Triwiyono, IPU.

2022 | Skripsi | S1 TEKNIK SIPIL

Kebutuhan lahan parkir meningkat seiring pertambahan jumlah penggunaan kendaraan pribadi. Hal ini mendorong pembangunan pada arah vertikal seperti pembangunan gedung bertingkat dan basement untuk memanfaatkan lahan. Terdapat tiga metode pemodelan gedung dengan basement yaitu pemodelan langsung, pemodelan terpisah struktur dan dinding basement, serta pemodelan terpisah struktur atas dan struktur basement. Gedung Laboratorium Bahan Bangunan DTSL FT UGM merupakan gedung dengan enam lantai dan satu basement yang hanya mampu mengakomodir 37% total kebutuhan parkir. Perancangan ulang struktur gedung tersebut dilakukan dengan penambahan satu lantai basement dan penggunaan dinding basement sebagai dinding penahan tanah yang menyatu pada rangka. Perancangan mencakup perencanaan balok, kolom dan dinding basement serta perhitungan kebutuhan volume netto beton dan rasio tulangan komponen struktur. Selain itu dilakukan perbandingan volume netto beton hasil perancangan ulang dengan dinding basement menyatu dan terpisah dari struktur. Pemodelan struktur dilakukan dengan bantuan aplikasi SAP 2000 v22 dan mengacu pada SNI 2847:2019, SNI 1726:2019 dan SNI 1727:2020. Pemodelan struktur terpisah untuk struktur atas dan struktur basement untuk memodelkan percepatan gempa pada permukaan tanah. Dari perancangan ulang struktur Gedung Laboratorium Bahan Bangunan DTSL FT UGM didapatkan kolom tipe K4 dan K5 perlu diperbesar dimensinya, sedangkan komponen struktur lainnya diperlukan perubahan konfigurasi tulangan. Rasio tulangan komponen kolom serta balok hasil perancangan ulang masih memenuhi persyaratan dalam SNI 2847:2019 dimana balok tidak lebih dari 2,5% dan diantara 1% - 6% untuk kolom. Diperoleh volume netto beton pada lantai basement 1 dan 2 pada elemen struktur balok, kolom, dan dinding penahan tanah sebesar 450,839 m3. Rasio perbandingan volume beton dinding basement perancangan ulang dengan dinding penahan tanah terpisah dan menyatu pada rangka sebesar 0,13.

The need for parking space increases along with the number of private vehicle use. This encourages the development of a vertical direction such as the construction of high-rise buildings and basements to utilize the existing land. There are three methods of modeling buildings with basements, namely direct modeling, separate modeling of structures and basement walls, and separate modeling of superstructures and basement structures. The FT UGM DTSL Building Materials Laboratory is a building which built with six floors and one basement, which is only able to accommodate 37% of the total parking needs.. The redesign of the building structure was done by adding one basement floor and using the basement wall as a retaining wall that is integrated with the building structure. The redesign includes the planning of beams, columns, basement walls, and calculating the net volume of concrete and the ratio of structural components reinforcement. Beside that, a comparison of the net volume of the redesigned concrete was carried out with the basement wall that integrated and separated from the structure. Structural modeling using SAP 2000 v22 and refers to SNI 2847:2019, SNI 1726:2019 and SNI 1727:2020. Structural modeling is done separately for the upper structure and the lower structure which includes the basement. From the redesign of the structure of the DTSL FT UGM Building Materials Laboratory, it is found that the dimensions of column type K4 and K5 need to be enlarged, while other structural components need the reinforcement configuration changes. The net volume of concrete on the 1st and 2nd basement floors for beams, columns, and retaining walls is 450.839 m3. The ratio of the reinforcement of the re-designed column and beam components still fulfill the requirements in SNI 2847:2019 where the beam is not more than 2.5% and the column is between 1% - 6%. The concrete volume ratio of basement wall for the redesign basement wall that separated and integrated with the structure frame is 0,13.

Kata Kunci : Balok, Kolom, Retaining Wall, Basement, Rasio Tulangan, Volume Netto, Pemodelan Terpisah