Pengaruh Desain Sistem Dan Attenuasi Potensial Proteksi Katodik Impressed Current Terhadap Struktur Tiang Pancang Di Pelabuhan Minyak PT. xXx
ARIF MAHMUDHI, Dr. Ir. Viktor Malau, D.E.A
2019 | Tesis | MAGISTER TEKNIK MESINPenentuan desain sistem Impressed Current Cathodic Protection di bagian luar struktur tiang pancang dermaga Oil Wharf -1 /2/3/4 di PT xXx Riau. Penelitian ini meliputi proses perhitungan kebutuhan arus dan jumlah tegangan DC keseluruhan sistem struktur. Selain itu diikuti dengan pemodelan matematika terkait pengaruh atenuasi struktur terhadap distribusi tegangan katodik. Pemodelan pemetaan sebaran tegangan telah berhasil dilakukan dan secara efektif telah dikontrol di lapangan. Hasil pembuktian di lapangan menunjukkan bahwa electrical continuity yang buruk antara sambungan struktur akan menyebabkan rendahnya distribusi tegangan katodik di sepanjang dermaga. Dalam kondisi sebenarnya, struktur tiang pancang tersebut akan menerima distribusi arus yang lebih kecil dibandingkan struktur lain. Secara alamiah, electrical continuity yang buruk akan meningkatkan tahanan dan mengurangi distribusi tegangan dari anode menuju struktur tiang pancang. Hasil penelitian menunjukkan bahwa dibutuhkan 76 anode tambahan dengan total kebutuhan arus DC 4000 Ampere dan dibagi menjadi 4 sistem ICCP, di mana kebutuhan tegangan untuk setiap sistem nya adalah DC 40 Volt. Jumlah anode yang dibutuhkan setiap sistem adalah 20 Anode.
Engineering design calculation for pile outer section of Oil Wharf-1/2/3/4 at PT xXx at Riau. This research including current requirement and DC voltage calculation followed by additional mathematical modeling structure. Modelling of attenuation simulation has been already successfully implemented and controlled at field. As per verification results from site, it has been identified that bad electrical continuity between structure section would cause worse distribution potential along and reading in accordance with accumulation result, for real condition, pile structure would receive less current flow from anode compare than lower one (good electrical continuity). Naturally, bad electrical continuity would increase resistance and decrease potential distribution from anode to section structure. The results showed that the new cathodic protection systems required 76 additional anode (MMO), with minimum amperage supply is 4000 A, divided into 4 systems, with minimum voltage supplied for each system are 40 Volt and anode number between each system are 20 ea.
Kata Kunci : Dermaga Jetty, Arus Tanding, Desain Engineering, Pemetaan Tegangan, Simulasi Atenuasi , Distribusi Tegangan.