Laporkan Masalah

SISTEM CITRA FOTOAKUSTIK SEDERHANA BERBASIS LASER DIODA DAN MIKROFON CONDENSER

HARRY MIYOSI S, Dr. Mitrayana, S.Si., M.Si.

2018 | Skripsi | S1 FISIKA

Telah dilakukan penelitian pencitraan fotoakustik untuk mendeteksi jaringan radang terhadap jaringan normal. Sistem citra fotoakustik yang dibuat menggunakan laser dioda sebagai sumber radiasi dan mikrofon condenser sebagai alat deteksi. Pada proses pengambilan citra, sumber radiasi dan detektor dibuat statis, sedangkan meja objek bergerak dalam arah X-Y. Sistem mekanik pada alat citra fotoakustik menggunakan ulir, ballscrew, dan motor stepper yang dikontrol oleh mikrokontoler. Sedangkan sistem pengambilan data mengunakan mikrofon (detektor) yang dikuatkan oleh soundcard behringer. Sistem mekanik dan detektor terintegrasi dan dikontrol oleh komputer melalui perangkat lunak komputer. Hasil karakterisasi sistem citra fotoakustik diperoleh pengaturan sistem optimum untuk mendeteksi jaringan radang yaitu frekuensi laser dioda dalam range > 15kHz dengan duty cycle modulasi 24%-36% karena sampel akan cendrung terbakar jika duty cycle > 50%, pergeseran stage minimum 0,02 milimeter, dengan kecepatan pengambilan data sampel 1 detik/pixel. Hasil citra jaringan radang umumnya memiliki intensitas fotoakustik yang tinggi sehingga menghasilkan kontras yang tinggi pada hasil citra fotoakustik dibandingkan jaringan normal.

A photoacoustic imaging study has been done to detect inflammatory tissue against normal tissue. The photoacoustic imaging system is made using a diode laser as a radiation source and condenser microphone as a detection device. In the scanning process, the radiation sources and detector is set in static state, while the object table moves in the X-Y direction. The mechanical system of the photoacoustic imaging device uses threaded, ballscrew, and stepper motors controlled by microcontoler. The data retrieval system using a microphone (detector) that is amplified by soundcard behringer. Mechanical systems and detectors are integrated and controlled by computer through computer software. The result of characterization of photoacoustic imaging system obtained by optimum system setting to detect inflammatory tissue which laser diode frequency in range > 15kHz with modulation duty cycle 24%-36% because sample will tend to burn if duty cycle > 50%, minimum shift of stage 0.02 millimeter, and sample data rate 1 second/pixel. Image of inflammatory tissue generally have a high photoacoustic intensity. Thus, produces a higher contrast in photoacoustic imaging results compared to normal tissue.

Kata Kunci : Fotoakustik, Pencitraan, Laser dioda, Mikrofon condenser.


    Tidak tersedia file untuk ditampilkan ke publik.